OSU COLLEGE OF BIOLOGICAL SCIENCES MSDS FILE

LOCTITE -- DURO 1M SUPER GLUE ADHESIVE REMOVER, 7651182
MATERIAL SAFETY DATA SHEET
FSC: 8040
NIIN: 00N061193
Manufacturer's CAGE: 08028
Part No. Indicator: A
Part Number/Trade Name: DURO 1M SUPER GLUE ADHESIVE REMOVER, 7651182
===========================================================================
                            General Information
===========================================================================
Company's Name: LOCTITE CORP
Company's Street: 4450 CRANWOOD PKY
Company's City: CLEVELAND
Company's State: OH
Company's Country: US
Company's Zip Code: 44128
Company's Emerg Ph #: 800-424-9300(CHEMTREC)
Company's Info Ph #: 216-663-3011
Safety Data Action Code: A
Record No. For Safety Entry: 001
Tot Safety Entries This Stk#: 001
Status: SMJ
Date MSDS Prepared: 11JAN93
Safety Data Review Date: 31JUL95
MSDS Preparer's Name: JEAN TOBBE
Preparer's Company: SAME
MSDS Serial Number: BXZSX
===========================================================================
                     Ingredients/Identity Information
===========================================================================
Proprietary: NO
Ingredient: ACETONE (SARA 313) (CERCLA)
Ingredient Sequence Number: 01
Percent: 85-90
Ingredient Action Code: A
NIOSH (RTECS) Number: AL3150000
CAS Number: 67-64-1
OSHA PEL: 1000 PPM
ACGIH TLV: 750 PPM;1000 STEL
-------------------------------------
Proprietary: NO
Ingredient: POLYOXYETHYL COCOAMINE
Ingredient Sequence Number: 02
Percent: <5
Ingredient Action Code: A
NIOSH (RTECS) Number: 1007415PA
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-------------------------------------
Proprietary: NO
Ingredient: WATER
Ingredient Sequence Number: 03
Percent: 5-10
Ingredient Action Code: A
NIOSH (RTECS) Number: ZC0110000
CAS Number: 7732-18-5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-------------------------------------
Proprietary: NO
Ingredient: ADDITIVES
Ingredient Sequence Number: 04
Percent: <2
Ingredient Action Code: A
NIOSH (RTECS) Number: 1000144AD
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
===========================================================================
                     Physical/Chemical Characteristics
===========================================================================
Appearance And Odor: CLEAR GEL; MILD ODOR.
Specific Gravity: 0.85
Evaporation Rate And Ref: NOT APPLICABLE
Solubility In Water: SLIGHTLY
===========================================================================
                      Fire and Explosion Hazard Data
===========================================================================
Flash Point: 0F,-18C
Flash Point Method: CC
Extinguishing Media: CO*2, FOAM, DRY CHEMICAL.
Special Fire Fighting Proc: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire And Expl Hazrds: VAPORS MAY CAUSE FLASH FIRE.
===========================================================================
                              Reactivity Data
===========================================================================
Stability: YES
Cond To Avoid (Stability): NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG OXIDIZERS.
Hazardous Decomp Products: HAZARDOUS PRODUCTS FORMED BY FIRE OR THERMAL
DECOMPOSITION: OXIDES OF CARBON.
Hazardous Poly Occur: NO
Conditions To Avoid (Poly): NOT RELEVANT
===========================================================================
                            Health Hazard Data
===========================================================================
LD50-LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry - Inhalation: YES
Route Of Entry - Skin: YES
Route Of Entry - Ingestion: YES
Health Haz Acute And Chronic: EYE IRRITANT. LOW TOXICITY BY INGESTION.
Carcinogenicity - NTP: NO
Carcinogenicity - IARC: NO
Carcinogenicity - OSHA: NO
Explanation Carcinogenicity: NOT RELEVANT
Signs/Symptoms Of Overexp: SEE HEALTH HAZARDS.
Med Cond Aggravated By Exp: NONE SPECIFIED BY MANUFACTURER.
Emergency/First Aid Proc: INGEST:CALL MD IMMEDIATELY (FP N). INHAL: REMOVE
IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK
ASSISTANCE FROM MD (FP N). SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD
(FP N).
===========================================================================
                   Precautions for Safe Handling and Use
===========================================================================
Steps If Matl Released/Spill: REMOVE ALL SOURCES OF IGNITION, VENTILATE.
SOAK UP IN INERT ABSORBENT W/NON-SPARKING TOOLS. FLUSH AREA W/WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Method: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). LANDFILL OR INCINERATE FOLLOWING EPA & LOCAL
REGULATIONS.
Precautions-Handling/Storing: STORE IN COOL, VENTILATED AREA. KEEP AWAY
FROM ALL SOURCES OF HEAT, FLAME & IGNITION.
Other Precautions: KEEP AWAY FROM EYES. OBSERVE NORMAL SAFETY PRECAUTIONS.
===========================================================================
                             Control Measures
===========================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: NONE SPECIFIED BY MANUFACTURER.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Suppl. Safety & Health Data: NONE SPECIFIED BY MANUFACTURER.
===========================================================================
                            Transportation Data
===========================================================================
===========================================================================
                               Disposal Data
===========================================================================
===========================================================================
                                Label Data
===========================================================================
Label Required: YES
Technical Review Date: 31JUL95
Label Date: 28JUL95
Label Status: B
Common Name: DURO 1M SUPER GLUE ADHESIVE REMOVER, 7651182
Chronic Hazard: NO
Signal Word: DANGER!
Acute Health Hazard-Slight: X
Contact Hazard-Slight: X
Fire Hazard-Severe: X
Reactivity Hazard-None: X
Special Hazard Precautions: EXTREMELY FLAMMABLE. ACUTE:EYE IRRITANT. LOW
TOXICITY BY INGESTION. CHRONIC:NONE LISTED BY MANUFACTURER.
Protect Eye: X
Protect Skin: X
Protect Respiratory: X
Label Name: LOCTITE CORP
Label Street: 4450 CRANWOOD PKY
Label City: CLEVELAND
Label State: OH
Label Zip Code: 44128
Label Country: US
Label Emergency Number: 800-424-9300(CHEMTREC)
=======================================================================
URL for this msds http://hazard.com.  If you wish to change, add to, or
delete information in this archive please sent updates to dan@hazard.com.