AVERY-DENNISON -- FLUORESCENT HI-LITER
INKS, 0005
MATERIAL SAFETY DATA SHEET
NSN: 751000N066681
Manufacturer's CAGE: 16956
Part No. Indicator: A
Part Number/Trade Name: FLUORESCENT
HI-LITER INKS, 0005
===========================================================================
General Information
===========================================================================
Company's Name: AVERY-DENNISON INC
Company's Street: 1 CLARK HILL
Company's City: FRAMINGHAM
Company's State: MA
Company's Country: US
Company's Zip Code: 01701
Company's Emerg Ph #: 508-879-0511
Company's Info Ph #: 800-252-8379
Record No. For Safety Entry: 001
Tot Safety Entries This Stk#: 001
Status: SMJ
Date MSDS Prepared: 21FEB92
Safety Data Review Date: 17NOV95
MSDS Serial Number: BZSBS
Hazard Characteristic Code: NK
===========================================================================
Ingredients/Identity Information
===========================================================================
Proprietary: YES
Ingredient: PROPRIETARY
Ingredient Sequence Number: 01
===========================================================================
Physical/Chemical Characteristics
===========================================================================
Appearance And Odor: COLORED LIQUID;
SLIGHT AMMONIA ODOR.
Boiling Point: >212F,>100C
Melting Point: N/A
Vapor Pressure (MM Hg/70 F): NIL
Vapor Density (Air=1): 5.1
Specific Gravity: 1.09 @ 25C
Evaporation Rate And Ref: <1.0
(BUTYL ACETATE =1)
Solubility In Water: 100%
===========================================================================
Fire and Explosion Hazard Data
===========================================================================
Flash Point: 350F,177C
Flash Point Method: COC
Lower Explosive Limit: N/A
Upper Explosive Limit: N/A
Extinguishing Media: FOAM, CARBON
DIOXIDE, DRY CHEMICAL.
Special Fire Fighting Proc: USE
NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). USE WATER SPRAY
TO COOL NEARBY CONTAINERS EXPOSED TO
FIRE.
Unusual Fire And Expl Hazrds: NONE.
===========================================================================
Reactivity Data
===========================================================================
Stability: YES
Cond To Avoid (Stability): NONE.
Materials To Avoid: ACIDS, OXIDIZING
MATERIALS.
Hazardous Decomp Products: CARBON
DIOXIDE, CARBON MONOXIDE.
Hazardous Poly Occur: NO
Conditions To Avoid (Poly): NOT
RELEVANT.
===========================================================================
Health Hazard Data
===========================================================================
LD50-LC50 Mixture: NONE SPECIFIED
BY MANUFACTURER.
Route Of Entry - Inhalation: YES
Route Of Entry - Skin: YES
Route Of Entry - Ingestion: YES
Health Haz Acute And Chronic: ACUTE
AND CHRONIC:NONE LISTED BY
MANUFACTURER.
Carcinogenicity - NTP: NO
Carcinogenicity - IARC: NO
Carcinogenicity - OSHA: NO
Explanation Carcinogenicity: NOT
RELEVANT.
Signs/Symptoms Of Overexp: SEE HEALTH
HAZARDS.
Med Cond Aggravated By Exp: NONE
SPECIFIED BY MANUFACTURER.
Emergency/First Aid Proc: INGEST:CALL
MD IMMEDIATELY (FP N). INHAL: REMOVE
TO FRESH AIR. SUPPORT BREATHING
(GIVE O*2/ARTF RESP) (FP N). EYES: FLUSH
WITH PLENTY OF WATER FOR AT LEAST
15 MINUTES, IF EYE IRRITATION OCCURS,
SEEK MEDICAL ATTENTION. SKIN:WASH
WITH SOAP AND WATER.
===========================================================================
Precautions for Safe Handling and Use
===========================================================================
Steps If Matl Released/Spill: SOAK
UP WITH ABSORBENT MATERIAL AND DISPOSE
OF, WASH AREA DOWN WITH PLENTY OF
WATER.
Neutralizing Agent: NONE SPECIFIED
BY MANUFACTURER.
Waste Disposal Method: DISPOSE OF
ACCORDING TO FEDERAL, STATE, LOCAL
REGULATIONS.
Precautions-Handling/Storing: NONE.
Other Precautions: NONE SPECIFIED
BY MANUFACTURER.
===========================================================================
Control Measures
===========================================================================
Respiratory Protection: NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: NONE SPECIFIED BY MANUFACTURER.
Protective Gloves: IMPERVIOUS GLOVES
(FP N).
Eye Protection: ANSI APPRVD CHEM
WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI
APPRVD EMERGENCY EYE WASH & DELUGE SHOWER
(FP N).
Work Hygienic Practices: NONE SPECIFIED
BY MANUFACTURER.
Suppl. Safety & Health Data:
USERS OF THE "L" VERSION OF HMIS SHOULD
CONSULT THE "LR" VERSION FOR ADDITIONAL
INFORMATION (FP N).
===========================================================================
Transportation Data
===========================================================================
===========================================================================
Disposal Data
===========================================================================
===========================================================================
Label Data
===========================================================================
Label Required: YES
Technical Review Date: 17NOV95
Label Date: 17NOV95
Label Status: G
Common Name: FLUORESCENT HI-LITER
INKS, 0005
Chronic Hazard: NO
Signal Word: CAUTION!
Acute Health Hazard-None: X
Contact Hazard-None: X
Fire Hazard-Slight: X
Reactivity Hazard-None: X
Special Hazard Precautions: ACUTE
AND CHRONIC:NONE LISTED BY MANUFACTURER.
Protect Eye: Y
Protect Skin: Y
Protect Respiratory: Y
Label Name: AVERY-DENNISON INC
Label Street: 1 CLARK HILL
Label City: FRAMINGHAM
Label State: MA
Label Zip Code: 01701
Label Country: US
Label Emergency Number: 508-879-0511
=======================================================================
URL for this msds http://siri.org.
If you wish to change, add to, or
delete information in this archive
please sent updates to dan@siri.org.